Maintenance and Care
32
Check
Behaviour yes/no
Remedial action
Use 50 mm object to stop
door wing from closing
Drive reverses when
contact with object is made
yes
no
• Leave all settings as they are
• Have door correctly adjusted by a person qualified to
do so
Automatic force cut-off
Adopt procedure described
in 'Emergency Release'
section
Emergency release can be
activated easily (pull 1x,
operator is unlocked)
yes
no • Adjust end switch for door CLOSED, or activate
backjump (DIP switch 6 ON)
• Repair emergency release or have it repaired
• Check door. See door maintenance instructions
Emergency release mechanism
Open/Close door whilst, at
same time, operating safety
switch unit
Door behaves in
accordance with setting of
DIP switch 1,2 or 3.
Safety LED is lit (only
marathon)
yes
no • Check wiring, tighten terminal connection
• Correctly adjust DIP switch
•
Take door drive mechanism out of operation and ensure
it cannot restart by accident. Contact after-sales service!
Safety switch unit, if provided
Open/Close door whilst, at
same time, interrupting the
light barrier
Door behaves in
accordance with setting of
DIP switch 1,2 or 3.
Safety LED is lit
(only marathon)
yes
no • Check wiring, tighten terminal connection
• Correctly adjust DIP switch
• Clean light barrier
• Correctly adjust light barrier
•
Take door drive mechanism out of operation and ensure
it cannot restart by accident. Contact after-sales service!
Light barrier, if applicable
Regular checks
Check safety devices regularly, every year at the very least, to ensure they function correctly (e.g. BGR 232).
Safety devices that are sensitive to pressure (e.g. safety switch unit) should be checked every four weeks to ensure they function correctly;
see pr EN 60335-2-95.
Possible cause
• Automatic cut-off of supply is
working as it should
• Door incorrectly adjusted
• Everything in order!
• The mechanical door and
drive components are
strained
• Emergency release is
defective
• Door jam
• Everything in order!
• Broken cable, loose terminal
• DIP switch maladjusted
• Switch unit defective
• Everything in order!
• Broken cable, loose terminal
• DIP switch maladjusted
• Light barrier soiled
• Light barrier maladjusted
(bent bracket)
• Light barrier defective
Comentários a estes Manuais