Marathon Sprint Series Instruções de Operação Página 33

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
Vista de página 32
Maintenance and Care
32
Check
Behaviour yes/no
Remedial action
Use 50 mm object to stop
door wing from closing
Drive reverses when
contact with object is made
yes
no
Leave all settings as they are
Have door correctly adjusted by a person qualified to
do so
Automatic force cut-off
Adopt procedure described
in 'Emergency Release'
section
Emergency release can be
activated easily (pull 1x,
operator is unlocked)
yes
no Adjust end switch for door CLOSED, or activate
backjump (DIP switch 6 ON)
Repair emergency release or have it repaired
Check door. See door maintenance instructions
Emergency release mechanism
Open/Close door whilst, at
same time, operating safety
switch unit
Door behaves in
accordance with setting of
DIP switch 1,2 or 3.
Safety LED is lit (only
marathon)
yes
no Check wiring, tighten terminal connection
Correctly adjust DIP switch
Take door drive mechanism out of operation and ensure
it cannot restart by accident. Contact after-sales service!
Safety switch unit, if provided
Open/Close door whilst, at
same time, interrupting the
light barrier
Door behaves in
accordance with setting of
DIP switch 1,2 or 3.
Safety LED is lit
(only marathon)
yes
no Check wiring, tighten terminal connection
Correctly adjust DIP switch
Clean light barrier
Correctly adjust light barrier
Take door drive mechanism out of operation and ensure
it cannot restart by accident. Contact after-sales service!
Light barrier, if applicable
Regular checks
Check safety devices regularly, every year at the very least, to ensure they function correctly (e.g. BGR 232).
Safety devices that are sensitive to pressure (e.g. safety switch unit) should be checked every four weeks to ensure they function correctly;
see pr EN 60335-2-95.
Possible cause
Automatic cut-off of supply is
working as it should
Door incorrectly adjusted
Everything in order!
The mechanical door and
drive components are
strained
Emergency release is
defective
Door jam
Everything in order!
Broken cable, loose terminal
DIP switch maladjusted
Switch unit defective
Everything in order!
Broken cable, loose terminal
DIP switch maladjusted
Light barrier soiled
Light barrier maladjusted
(bent bracket)
Light barrier defective
Vista de página 32
1 2 ... 28 29 30 31 32 33 34 35

Comentários a estes Manuais

Sem comentários