FINE VOLTAGE ADJUSTMENT
Adjustment of the output voltage from the generator is necessary to provide the correct voltage to the end of the
power line. Voltage adjustment can be carried out at any time on the Voltage Adjust screen.
1. With the unit running, press .
2. Press . The voltages displayed will begin flashing.
3. Use and to adjust the voltage.
4. Press to confirm the new voltage. The voltages displayed will stop flashing.
SHUTTING DOWN THE UNIT
Check with personnel using power supplied by the generator and let them know that the power is going to be turned
off. Make sure the power shut down will not create any hazards by accidentally turning off equipment that needs to
be kept on (pumps, compressors, lights, etc.).
1. Remove all loads from the generator by opening all circuit breakers (turn to the OFF (O) position).
2. Let the engine run for approximately five minutes to allow it to cool down.
3. Push O. Pressing the red Engine Stop/Reset (O) button will result in the generator going into the shutdown cycle
and starting a 15 second shutdown timer called stopping. If the unit does not shut down within 15 seconds, a
stop fail alarm will be displayed on the LCD window.
4. After the unit shuts down, move the Control Power switch to the OFF (O) position.
Note: For extended storage time, disconnect the battery. Refer to the engine operators manual for extended storage
requirements.
EXHAUST FILTER CLEANING OPERATIONS
When enabled, the exhaust filter system goes through an automatic cleaning process known as regeneration. Under
normal circumstances, regeneration occurs without interruption of unit operation and with minimal operator involve-
ment. In the event there are conditions requiring the operation of the unit with the auto exhaust filter cleaning disabled,
the operator may be required to perform procedures to enable or disable the auto exhaust filter cleaning. The operator
may also be required to perform a manual regeneration. The following procedures describe how to perform these
functions.
00396
Manual Mode
GEN
V
+
-
Voltage Adjust
- Press , voltage will begin flashing
- Use and arrows to adjust voltage
- Press to confirm new voltage. Numbers will stop flashing
V
L-N Average
L-L Average
V
480
277
V
+
-