8 Endurance FTvirtual Server Release Notes
What You Need to Know About This Release
Boot Options
The Endurance software requires that certain switches be present on the command line in the
CoServer’s
boot.ini file. The required switches differ depending upon the Windows service
pack level.
• After the Endurance software has been installed on a CoServer that is running Windows
Server 2003 with no service pack, or after all service packs have been removed from a
CoServer, ensure that the CoServer
boot.ini file contains the following options:
- For a CoServer in Online Endurance CoServer mode:
/MAXMEM=256
/ONECPU
- For a CoServer in Offline Endurance CoServer mode:
/MAXMEM=256
/ONECPU
/NOMTC
• After the Endurance software has been installed on a CoServer running Windows Server
2003 Service Pack 1, or after a CoServer has been upgraded to Service Pack 1, ensure that
the CoServer
boot.ini file contains the following options:
- For a CoServer in Online Endurance CoServer mode:
/MAXMEM=256
/ONECPU
/EXECUTE
- For a CoServer in Offline Endurance CoServer mode:
/MAXMEM=256
/ONECPU
/EXECUTE
/NOMTC
If the boot.ini file is modified to add or remove the /EXECUTE switch (or the related
/NOEXECUTE switch)in a way that is inconsistent with the service pack level, the Endurance
software will detect the change and modify the
boot.ini file to restore consistency. The
CoServer or the FTvirtual Server may not boot properly if these switches are not correct.
Data Execution Protection
The Endurance software precludes the use of hardware-based Data Execution Protection (DEP)
in both the CoServer and FTvirtual Server environments. Software DEP is not affected.